Farsince 22AWG 4C Stranded Unshielded Fire Alarm/Control Cable, Red PVC Jacket, FPL/CL2 1
Farsince 22AWG 4C Stranded Unshielded Fire Alarm/Control Cable, Red PVC Jacket, FPL/CL2 2
Farsince 22AWG 4C Stranded Unshielded Fire Alarm/Control Cable, Red PVC Jacket, FPL/CL2 1
Farsince 22AWG 4C Stranded Unshielded Fire Alarm/Control Cable, Red PVC Jacket, FPL/CL2 2

Farsince 22AWG 4C Stranded Unshielded Fire Alarm/Control Cable, Red PVC Jacket, FPL/CL2

Flexible 22/4 unshielded cable for power‑limited fire alarm, security, and low‑voltage control circuits.
5.0
Model No.:
FS43A00
Brand:
Farsince / OEM
MOQ:
500
Trade Term:
EXW / FOB Ningbo
Lead time:
2–4 weeks
Customization:
Supported
Sample:
Available
Warranty:
1 Year
design customization

    oops...!

    no product data.

    Go to homepage

    Description

    Farsince’s 22 AWG, 4‑conductor unshielded cable is designed for dependable performance in fire alarm and low‑voltage signaling systems. Stranded bare copper conductors provide easy pulling and reliable terminations, while color‑coded insulation simplifies device wiring and polarity. The red PVC jacket clearly identifies life‑safety cabling and is suitable for general‑purpose in‑wall installations where FPL/CL2 is permitted. Ideal for smoke/heat detectors, pull stations, control/monitor modules, door holders, annunciators, and general security/access control wiring. For riser shafts or plenum air spaces, choose Farsince FPLR or FPLP variants as required by code.



    Specifications

    • Gauge/Conductors: 22 AWG, 4 conductors, stranded (22/4 STR)
    • Conductor Material: Bare copper
    • Shielding: Unshielded (U)
    • Insulation: PVC, color‑coded cores for polarity
    • Jacket: Red PVC, indoor general‑purpose
    • Ratings: FPL (Power‑Limited Fire Alarm) and/or CL2 (Class 2) options available; verify listing per part number
    • Voltage Class: 300 V power‑limited circuits (typical)
    • Applications: Fire alarm IDC loops, NACs, control/relay wiring, annunciators; also access control, intercom, and low‑voltage signaling
    • Installation Notes: Use FPL for general spaces; select FPLR or FPLP for riser/plenum areas per NEC/local AHJ requirements
    • Packaging: Reel or reel‑in‑box; common lengths 500 ft and 1000 ft (305 m)